Custom Query (964 matches)
Results (775 - 777 of 964)
Ticket | Owner | Reporter | Resolution | Summary |
---|---|---|---|---|
#924 | Done | Upated io_type error message | ||
Description |
Several users failed to update their application roms.in when the ROMS code is updated to include changes to its standard input file. They get errors like: INITIAL: Configuring and initializing forward nonlinear model ... ******* GET_GRID - Illegal output type, io_type = 0 Found Error: 03 Line: 91 Source: ROMS/Utility/get_grid.F Found Error: 03 Line: 85 Source: ROMS/Utility/set_grid.F This error implies that the PIO block is missing in roms.in: ! Input and Output files processing library to use: ! ! [1] Standard NetCDF-3 or NetCDF-4 library ! [2] Serial or Parallel I/O with Parallel-IO (PIO) library (MPI only) INP_LIB = 1 OUT_LIB = 1 ! PIO library methods for reading/writing NetCDF files: ! ! [0] parallel read and write of PnetCDF (CDF-5, not recommended) ! [1] parallel read and write of NetCDF3 (64-bit offset) ! [2] serial read and write of NetCDF3 (64-bit offset) ! [3] parallel read and serial write of NetCDF4/HDF5 ! [4] parallel read and write of NETCDF4/HDF5 PIO_METHOD = 2 ! PIO library MPI processes set-up: PIO_IOTASKS = 1 ! number of I/O tasks to define PIO_STRIDE = 1 ! stride in the MPI-ran between I/O tasks PIO_BASE = 0 ! offset for the first I/O task PIO_AGGREG = 1 ! number of MPI-aggregators to use ! PIO library rearranger methods for moving data between computational and I/O ! processes: ! ! [1] Box rearrangement ! [2] Subset rearrangement PIO_REARR = 1 ! PIO library rearranger flag for MPI communications between computational ! and I/O processes: ! ! [0] Point-to-Point (low-level communications) ! [1] Collective (high-level grouped communications) PIO_REARRCOM = 0 ! PIO library rearranger flow control direction flag for MPI communications ! between computational and I/O processes: ! ! [0] Enable computational to I/O processes, and vice versa ! [2] Enable computational to I/O processes only ! [3] Enable I/O to computational processes only ! [4] Disable flow control PIO_REARRDIR = 0 ! PIO rearranger options for computational to I/O processes (C2I): PIO_C2I_HS = T ! Enable C2I handshake (T/F) PIO_C2I_Send = T ! Enable C2I Isends (T/F) PIO_C2I_Preq = 64 ! Maximum pending C2I requests ! PIO rearranger options for I/O to computational processes (I2C): PIO_I2C_HS = T ! Enable I2C handshake (T/F) PIO_I2C_Send = T ! Enable I2C Isends (T/F) PIO_I2C_Preq = 65 ! Maximum pending I2C requests Therefore, this update clarifies the standard output error as: INITIAL: Configuring and initializing forward nonlinear model ... ******* GET_GRID - Illegal input file type, io_type = 0 Check KeyWord 'INP_LIB' in 'roms.in'. Found Error: 02 Line: 91 Source: ROMS/Utility/get_grid.F Found Error: 02 Line: 85 Source: ROMS/Utility/set_grid.F Let's hope that we don't see desperate messages in the Forum from users about this error, and they have the curiosity to check their roms.in and find that the INP_LIB or OUT_LIB KeyWords are not found, indicating an old version of roms.in, which needs to be updated. |
|||
#925 | Done | VERY IMPORTANT: Updated nesting connetivity tool contact.m | ||
Description |
This is an essential update to the ROMS nesting connectivity tool contact.m. In particular, the local function refine_coordinates is enhanced to be more robust for Cartesian and Spherical nested grid applications when computing ROMS metric variables. I added the following critical information to contact.m header:
|
|||
#926 | Fixed | IMPORTANT: Corrected couple of bugs | ||
Description |
|