Opened 14 years ago
Closed 14 years ago
#476 closed defect (Fixed)
point source values replaced by FillValue — at Version 1
Reported by: | jcwarner | Owned by: | arango |
---|---|---|---|
Priority: | major | Milestone: | Release ROMS/TOMS 3.4 |
Component: | Nonlinear | Version: | 3.4 |
Keywords: | Cc: |
Description (last modified by )
Another reason why the FillValues give me a headache: Most users place point sources at locations where the u- or v-mask is zero (i.e. land). During the simulation the model will actually compute a source value at that 'land' location and those transports are used in the simulation. However, when writing history or other output files, the u- or v-values at the ppoint source locations will be replaced with FillValues.
This does not allow the user to check if the correct transport is being introduced into the model. Please negate the FillValue at locations of the point sources. Suggested fix: make up a temporary u/vmask that does not mask the point sources in wrt_his.F send that temporary mask to nf_fwite3d instead of GRID(ng)%umask.
Change History (1)
comment:1 by , 14 years ago
Description: | modified (diff) |
---|---|
Resolution: | → Fixed |
Status: | new → closed |
Summary: | point source values replaced by fillvalue → point source values replaced by FillValue |
Type: | bug → defect |
Yes, thank you. This was a good one and it required complicate fixes and testing: