Ticket | Owner | Reporter | Resolution | Summary |
---|---|---|---|---|
#314 | Fixed | wet_dry v2dbc | ||
Description |
1) ROMS/Nonlinear/v2dbc_im.F has a RETURN (line 787) that prevents execution of the WET_DRY algorithm on the boundaries. Please move the location of the RETURN statement to be located at the end of the routine (line 874). 2) ROMS/Nonlinear/set_data.F suggest that the WET_DRY catches for BOUNDARY(ng)%zeta_* be moved (from lines 868-909) to line 721. This would place the catches immediately after the zeta_* fields are set, and thus before the zeta_* fields may be used in ana_m2obc or any other place. |
|||
#315 | Fixed | Wrong CPP directive in congrad.F | ||
Description |
Corrected CPP directive in congrad.F when W4DPSAS is activated. We need to have: # if defined W4DPSAS || defined TL_W4DPSAS || \ defined W4DPSAS_SENSITIVITY instead of # if defined TL_W4DPSAS || defined TL_W4DPSAS || \ defined W4DPSAS_SENSITIVITY Many thanks to Andy Moore for reporting this bug. I also corrected the reporting of ADJUST_BOUNDARY, ADJUST_STFLUX, and ADJUST_WSTRESS when running other adjoint-based algorithms. |
|||
#316 | Fixed | Upated matlab scripts to compute ROMS vertical coorditnates | ||
Description |
Removed the restriction that hc, the critical thickness controlling the vertical transformation, needs to be less or equal than the minimum depth (hmin) of a particular application when using Vtransform=2. Actually, hc can be any positive value and the tranformation works in both cases when hc < hmin and hc > 0. This is one of the main advantages of the new transformation. This restriction only applies for the old transformation Vtransform=1. |