Ticket Owner Reporter Resolution Summary
#133 arango arango Fixed Typo in inp_par.F stations output fields switch
Description

Corrected a typo in inp_par.F during the reading of the stations output fields logical switch. Changed Hout(idBott) to Sout(idBott). Many thanks to J.Paul Rinehimer for reporting this bug.

#134 arango m.hadfield Fixed Float restart (FRREC) does not work
Description

As I reported on the user forum on 22 Nov 2006 (title "Restarting floats"),

ROMS floats files contain a variable FRREC which, in the same way as NRREC, is supposed to allow float trajectories to be carried over a model restart from one run to another (or so I surmise). Has anyone actually achieved this? It doesn't work for me. As far as I can see, DEF_FLOATS is only called (from OUTPUT) if LdefFLT is true, but the restart code in DEF_FLOATS is only executed if LdefFLT is false.

This still doesn't work. When I set FRREC to a non-zero value, the float positions are not read from the floats file and a new floats file is created, overwriting the existing one. I will attempt to come up with a solution if I can, but in the meantime am submitting this ticket to record the problem.

#135 arango arango Done Updated ROMS plotting package
Description

Added a few new fields to plot. The ncgm2gif script was updated to use either Image Magic or IMTOOLS. I also update the copyright to the entire package.